PC version · recommended
The QTc measurement app
Unzip the file and open qtc.html in a browser. You can also try it right on this site without downloading (on a phone you can see what the screen looks like).
Updated 2026.9.8
Web app · tangent method
Just paste an ECG image and the app measures the QT interval by the tangent method and calculates QTc (Bazett and Fridericia). The results come out as text you can paste straight into an electronic medical record. The interface is in Japanese.
Latest version 2.52026/9/8 update
Features
Paste (or drag in) an ECG image and the app measures QT for each beat in the image and shows the average. It is designed for images of about seven beats.
The end of the T wave is where a tangent drawn on the downslope of the T wave meets the baseline. All markers are shown on screen and can be corrected by hand.
In addition to 12-lead ECGs at 100% and 200%, there is a setting for Holter ECGs. It can also read Holter images with gray grids.
It runs from a single HTML file and does not use the internet. Copy it to an electronic medical record terminal and open it in Edge to use it inside the hospital system.
Download
qtc.html is the app itself. The zip contains the app and nine sample ECGs to try right away.
PC version · recommended
Unzip the file and open qtc.html in a browser. You can also try it right on this site without downloading (on a phone you can see what the screen looks like).
Updated 2026.9.8
Phone version
Take a photo of a paper ECG with your phone, drag a box around the two beats you want to analyze, and confirm. Accuracy is still not great.
A specification of how the analysis works, written by AI. To be honest, I can't make sense of it myself. (In Japanese.)
How to use
Unzip the file and open qtc.html in Edge or Chrome.
For a 12-lead ECG, the basic use is to cut out leads II and V5 and paste them, but any lead can be measured. Start by dragging a sample ECG from the zip into the drop area.
Choose the scale at which the ECG is displayed: 100%, 200% or Holter (ホルター). At 100% accuracy is a little uncertain; at 200% my impression is that it stays within about ±5 ms.
Check the markers on each beat. If they are off, you can correct them by hand.
The baseline and tangent can be moved by dragging. Add an R wave with Shift + click.
Press Copy results (解析結果をコピー) and text like the following is copied to the clipboard, ready to paste into an electronic medical record (the lead labels are in Japanese).
2誘導 : HR 66, QT 344, QTcB 362, QTcF 356 (3beats) V5誘導 : HR 67, QT 336, QTcB 355, QTcF 349 (4beats)
Movie
Calibration
Calibration sets how many pixels in the image correspond to how many seconds. Normally it is read automatically.
Each time you paste an image, calibration is read automatically from the grid. It used to be manual because automatic reading was not accurate enough, but the algorithm was rebuilt in ver. 2.4 and now reads within ±0.5% at 100%, 200% and Holter.
For images without a grid, when automatic reading fails, or when the value looks wrong, you can still adjust it manually.
After adjusting manually, press Reset (再設定) to save the value on the computer. From then on, the saved value is used whenever you press the 100%, 200% or Holter button. The value depends on the display, so set it once on each computer.
Troubleshooting
About
I have been hooked on AI lately and made an app that measures QTc by the tangent method. I started building it with Claude Opus 4.6, but I kept hitting the usage limit, so I also use Google Antigravity.
It is something like a toy made by an amateur, and its accuracy has issues, but please give it a try. I would be glad to hear what you think.
When I heard that Dr. Yoshinaga measures QT in three beats at each of five points in a Holter ECG, 15 beats in all, I thought I could never do that. With this tool, 15 beats can be measured with five drags.